R&S®NGPE 40/40 Programmable Power Supply
For Use in Test Systems and for general laboratory applications
Specifications in Brief
| Voltage setting, in 4 digits | 0 V to 39.99 V | |
| Resolution/Deviation | 10 mV (4000 steps)/<10–3 of full scale | |
| Current setting, in 3 digits | 0 A to 39.9 A | |
| Resolution/Deviation | 100 mA (400 steps)/ <2×10–3 of full scale | |
| Constant-voltage source | ||
| Deviation of output voltage | ||
| with ±10 % AC supply variation | <10–4 | |
| between 0 °C and 45 °C | <2 × 10–5/°C | |
| with 10 % to 90 % nominal current | <10–4 | |
| Transient recovery time at 40 V | ||
| from 2 A to 18 A or conversely | 2.0 ms (to 150 mV) | |
| from 2 A to 4 A or conversely | 0.2 ms (to 50 mV) | |
| from 16 A to 18 A or conversely | 0.2 ms (to 50 mV) | |
| Setting time | without load | with load |
| from 0 V to 39 V | 50 ms | 60 ms |
| from 39 V to 0.4 V | 100 ms | 30 ms |
| from 39 V to 0.1 V | 120 ms | 40 ms |
| PARD, Vrms/Vp | 2 mV/20 mV | |
| Constant-current source | ||
| Deviation of output current | ||
| with ±10 % AC supply variation | <10–4 | |
| between 0 °C and +45 °C | <10–4/°C | |
| with 10 % to 90 % nominal voltage | <10–4 | |
| PARD, Irms | <40 mA | |
| Remote control | IEC 625-1 (IEEE 488) | |
| Functions | SH0, AH1, T0, TE0, L1, LE0, SR0, RL1, PP1, DC1, DT1, C0 | |
| Remote sensing | compensation for 0.5 V per lead | |
| Panel meters | ||
| Voltmeter (2 ranges) | 10/40 V ±2.5 % of full scale | |
| Ammeter (2 ranges) | 4/40 A ±2.5 % of full scale | |
| Monitoring output | ||
| for current | 400 mV corresp. to 4 A, 2 % of fs 400 mV corresp. to 40 A, 0.2 % of fs | |
| for voltage | 0 V to 40 V, 0.2 % of fs | |
| General data | ||
| Overvoltage protection (OVP) | 4.5 V to 50 V | |
| AC supply, selectable | 95 V to 135 V or 190 V to 265 V, 47 Hz to 63 Hz, 1600 VA | |
| Dimensions (W × H × D) | 492 mm × 161 mm × 420 mm (19.37 in × 6.34 in × 16.54 in) | |
| Weight 14 kg | (30.86 lb) | |